Power Quality Diagnostics & Energy Efficiency Management Service

This service identifies the root causes of harmonic distortion, voltage deviation, three-phase imbalance, voltage fluctuation, and voltage sags through on-site measurement, data acquisition, and professional analysis, while also assessing energy consumption structure and efficiency. It provides traceable and verifiable data for equipment selection, mitigation scheme design, grid connection acceptance, troubleshooting, and energy efficiency optimization.

With over 20 years of experience in power electronics and power quality, and leveraging its in-house mitigation equipment (SVG, APF, DVR) and energy management capabilities, Sanhe Power offers a one-stop service from testing and diagnosis to consulting and mitigation/energy efficiency implementation for both domestic and international customers.
  • PQM Diagnostics

  • sanhe

Availability:

PDF Export

Power Quality Diagnostics & Energy Efficiency Management Service

Provider: Sanhe Power Tech (Shenzhen) Co., Ltd.
Applicable to: Renewable energy plants, industrial & commercial parks, industrial users, data centers, energy storage systems, overseas projects


1. Service Overview

This service identifies the root causes of harmonic distortion, voltage deviation, three-phase imbalance, voltage fluctuation, and voltage sags through on-site measurement, data acquisition, and professional analysis, while also assessing energy consumption structure and efficiency. It provides traceable and verifiable data for equipment selection, mitigation scheme design, grid connection acceptance, troubleshooting, and energy efficiency optimization.

With over 20 years of experience in power electronics and power quality, and leveraging its in-house mitigation equipment (SVG, APF, DVR) and energy management capabilities, Sanhe Power offers a one-stop service from testing and diagnosis to consulting and mitigation/energy efficiency implementation for both domestic and international customers.




2. Problems We Help Solve

Customer Issue

Possible Cause

What Diagnostics Confirms

High electricity bills, power factor below standard

Insufficient reactive compensation, harmonic pollution

Power factor level, reactive power demand, harmonic share

Equipment frequently tripping or shutting down

Voltage sags, harmonic resonance, three-phase imbalance

Event waveforms, disturbance source location, sensitivity of critical equipment

Renewable grid connection requires rectification

Harmonics, voltage deviation, flicker exceeding limits

Whether power quality at the point of connection meets standards

Abnormal heating of capacitors or transformers

Harmonic amplification, parallel resonance

Harmonic flow analysis, resonance risk assessment

Precision equipment malfunction, rising defect rate

Voltage fluctuation, interharmonics, voltage sags

Power quality statistics and event records

Energy costs high but unclear where to optimize

Unclear energy flow, low equipment efficiency, no sub-metering

Energy consumption structure, efficiency baseline, energy-saving potential

Carbon data cannot be verified

Unclear energy flow, blurred metering boundaries

Energy and carbon accounting boundary clarification

Overseas projects need to comply with local grid codes

Different standards, harmonic/flicker limits

Assessment against IEEE 519, IEC 61000, EN 50160




3. Service Content

3.1 On-Site Power Quality Testing

Comprehensive testing covers the following parameters, based on national and international standards:

Test Item

Reference Standard

Core Value

Supply voltage deviation

GB/T 12325-2008 / EN 50160

Assess voltage deviation from rated value

Power system frequency deviation

GB/T 15945-2008

Assess frequency stability

Harmonics (2nd–50th order)

GB/T 14549-1993 / IEC 61000-4-30 Class A / IEEE 519

Identify harmonic sources and risks to transformers/capacitors

Three-phase voltage/current imbalance

GB/T 15543-2008 / IEC 61000-4-30

Assess negative-sequence impact on motors and precision equipment

Voltage fluctuation and flicker

GB/T 12326-2008 / IEC 61000-4-15

Assess interference with sensitive loads

Voltage sags/swells/short interruptions

IEC 61000-4-30 / GB/T 30137

Record event waveforms and locate the source of voltage dips

Interharmonics (0.5th–49.5th order)

GB/T 24337-2009

Assess low-frequency interharmonic impact

Power and power factor

—

Assess reactive power demand and energy efficiency

Measurement method: Power quality analyzers compliant with IEC 61000-4-30 Class A are used, with a basic measurement interval of 10 cycles, ensuring data accuracy and comparability. For overseas projects, assessment can be based on IEEE 519, EN 50160, and other international standards.

3.2 Power Quality Consulting & Assessment

Consulting Item

Content

Deliverable

Power quality status assessment

Assess power quality risks of existing or planned systems based on single-line diagrams, load lists, and operating data

Power Quality Assessment Report

Harmonic flow and resonance analysis

Build system impedance models, analyze harmonic amplification and parallel resonance risks

Harmonic Analysis Calculation Report

Mitigation scheme design and selection consulting

Provide SVG/APF/DVR capacity calculation, installation location recommendations, and scheme comparison

Mitigation Scheme Recommendation

Grid compliance consulting

Assess grid connection compliance against GB/T, IEEE 519, EN 50160, etc.

Compliance Assessment Opinion

Power quality training

Training for electrical O&M teams on fundamentals, standards, and equipment maintenance

Training materials and records

Third-party technical review

Independent review of mitigation schemes proposed by customers or third parties

Review Opinion

3.3 Energy Efficiency Management

Beyond power quality, the service assesses energy consumption structure and efficiency, identifying energy-saving opportunities and supporting energy/carbon management:

Service Item

Content

Deliverable

Energy consumption structure analysis

Collect and analyze electricity, gas, water, heat, and other energy data to clarify energy flow and consumption distribution

Energy Consumption Analysis Report

Energy efficiency baseline assessment

Establish energy efficiency baselines for main equipment and systems (motors, chillers, air compressors, pumps, etc.)

Energy Efficiency Baseline Report

Energy-saving potential analysis

Identify energy waste points and quantify energy-saving potential (load shifting, equipment upgrades, operational optimization, etc.)

Energy-Saving Potential Analysis

Energy management system (EMS) consulting

Assess the need for an energy management platform and provide functional requirements and deployment recommendations

EMS Requirements Recommendation

Carbon accounting support

Support energy-related carbon accounting boundary definition and data organization (Scope 1 & 2)

Carbon Accounting Data Support

Energy efficiency optimization recommendations

Provide actionable energy efficiency improvement measures with preliminary investment and payback estimates

Energy Efficiency Optimization Proposal




4. International Business Support

Support Area

Details

Standard adaptation

Testing and assessment can be based on IEEE 519, IEC 61000 series, EN 50160, and other international standards

Overseas on-site service

On-site power quality testing and energy efficiency assessment in Southeast Asia (Thailand, etc.), the Middle East, Europe, and other regions

Diagnosis-to-mitigation linkage

Test conclusions directly support the selection and configuration of in-house SVG/APF/DVR solutions, enabling integrated "diagnosis–mitigation" delivery

Project support

Can work with overseas EPC contractors or owners to perform testing and diagnosis per international standards




5. Service Process

Stage

Content

Deliverable

1. Requirement discussion

Clarify diagnostic objectives, measurement points, evaluation standards, and monitoring period

Diagnostic Plan Confirmation

2. Site survey

Confirm wiring conditions, safety measures, and CT/switchgear status

Site Survey Record

3. Instrument installation

Install power quality analyzers and energy meters at agreed points

Installation Record

4. Continuous monitoring

Collect power quality and energy consumption data over the set period

Raw Data Files

5. Data analysis

Perform statistics per standards and analyze energy efficiency

Data Analysis Table

6. Report issuance

Compile diagnostic and energy efficiency report with recommendations

Power Quality & Energy Efficiency Diagnostic Report




6. Deliverables

Core Content of the Diagnostic Report


Diagnostic overview: measurement points, voltage levels, monitoring period, instrument models, calibration information



Power quality statistics: 95% probability values, maximum, minimum, compliance rates for each parameter



Exceedance analysis: item-by-item comparison against standard limits



Event records: waveforms, duration, residual voltage of voltage sag/swell events



Root cause identification: preliminary identification of disturbance sources



Mitigation recommendations: equipment selection direction (SVG/APF/DVR) and capacity estimation



Compliance opinion: compliance assessment against grid connection standards



Energy consumption analysis: energy structure, efficiency baseline, energy-saving potential



Energy efficiency recommendations: actionable measures with preliminary investment and payback estimates



Carbon accounting support: boundary definition and data organization for Scope 1 & 2





7. Service Tiers

Tier

Name

Content

Application

L1

Digital preliminary diagnosis (remote/desktop)

Rapid assessment based on bills, single-line diagrams, and load lists; preliminary opinion within 3–5 working days

Early project stage, limited budget

L2

On-site power quality testing

Continuous monitoring per IEC 61000-4-30 Class A

Grid connection acceptance, troubleshooting

L3

Comprehensive diagnosis + energy efficiency

Testing + consulting + mitigation/energy efficiency recommendations

Mitigation project initiation, energy efficiency optimization




8. Technical Advantages

Dimension

Description

Standard compliance

Measurement methods comply with IEC 61000-4-30 Class A; statistics align with national standards; assessment can be based on international standards

Diagnostic independence

Conclusions are not tied to equipment sales; customers may choose their own mitigation scheme or supplier

In-house equipment

Own SVG/APF/DVR product lines; diagnostic conclusions directly support mitigation scheme design and equipment selection

Energy efficiency integration

Combines power quality diagnosis with energy consumption analysis, avoiding fragmented assessments

Engineering experience

Has served Sinopec, CNPC, CNOOC, PipeChina, and other major enterprises

Global delivery

Overseas project experience in the UK, Saudi Arabia, Malaysia, Cambodia, etc.




9. Customer Privacy Protection

Before project commencement, Sanhe Power can sign a Non-Disclosure Agreement (NDA) with the customer, specifying confidentiality obligations for distribution system, load characteristics, operating data, and other information obtained during diagnostics. Without the customer's written permission, such data will not be used for purposes other than this project or disclosed to third parties.




10. Cooperation Models

Model

Application

Description

Single diagnostic service

Grid connection acceptance, troubleshooting, dispute evidence

Priced by measurement points and monitoring period

Single consulting/energy efficiency assessment

Scheme review, harmonic analysis, energy efficiency potential analysis

Priced by project scope

Diagnosis + consulting + energy efficiency package

Diagnose, assess, then optimize

Fees can be packaged

Annual framework service

Regular power quality and energy efficiency inspections

Signed annually, covering multiple assessments and priority response

Diagnosis + mitigation/energy efficiency integration

Mitigation or energy efficiency improvements required after diagnosis

Diagnostic or consulting fees partially deductible from subsequent equipment purchases

Overseas project support

Overseas renewable energy/industrial projects

Can work with EPC contractors or owners per international standards




11. Information Required from Customers

Information Item

Description

Single-line diagram / distribution system diagram

Determine measurement points and system topology

Voltage level and transformer capacity

Assess short-circuit capacity and background harmonics

Main load types

Non-linear loads such as VFDs, rectifiers, arc furnaces, EV chargers

Energy consumption data

Electricity, gas, water, heat bills and sub-metering data (if available)

Diagnostic purpose

Grid connection acceptance / troubleshooting / mitigation / energy efficiency / carbon accounting

Monitoring period or consulting scope

24 hours / 7 days / as required; single item or overall assessment




12. Frequently Asked Questions

Q1: Does diagnostics require a power outage?
A: Routine on-site testing uses clamp-on or split-core CTs, requiring no power outage.

Q2: How long does monitoring take?
A: Routine monitoring is 24 hours to 7 days, depending on the diagnostic purpose.

Q3: Can the report be used for grid connection applications?
A: Yes. It is compiled per GB/T 14549, GB/T 12325, and other standards, with measurement methods compliant with IEC 61000-4-30 Class A. For overseas projects, reports can be issued against IEEE 519, EN 50160, etc.

Q4: Must mitigation equipment be purchased after issues are identified?
A: Not necessarily. The report provides technical judgment and recommendations; customers may choose their own mitigation scheme or supplier. Diagnostic services remain independent and objective.

Q5: What information is needed for remote preliminary diagnosis?
A: Bills, single-line diagram, load list, transformer capacity, and operating condition description. Preliminary opinion within 3–5 working days.

Q6: Can on-site diagnostics be provided for overseas projects?
A: Yes. Specific arrangements depend on project location and schedule.

Q7: How is customer data kept confidential?
A: A Non-Disclosure Agreement (NDA) can be signed before project commencement. Without written permission, data will not be used for other purposes or disclosed to third parties.

Q8: Can energy efficiency management be combined with power quality diagnosis?
A: Yes. The service can combine power quality testing with energy consumption analysis to identify both power quality risks and energy-saving opportunities, avoiding fragmented assessments.




Sanhe Power Tech (Shenzhen) Co., Ltd.
yvonne.zhang@samwha-cn.com
www.sanhenergy.com

From diagnosis and consulting to mitigation and energy efficiency implementation — verifiable data and technical support for your power quality and energy performance.



Previous: 
Next: 

About Us

We have been specialized in power quality,EnMS and Electrical engineering. We take advantages of lean production, product design, engineering management, project service etc.

Quick Links

Product Category

Contact Us

Tel: +86-13502854349
Whatsapp: +86-13418990147
E-Mail: yvonne.zhang@samwha-cn.com

Subscribe Now

Copyright© 2023 Sanhe Power Tech (Shenzhen) Co., Ltd. All Rights Reserved.| Sitemap  | Support By Leadong