BAM Three Phase Capacitor

  • capacitive power factor correction for medium voltage system

  • BAM4.16-500-3

  • indoor / outdoor

  • Sanhe

Availability:

PDF Export

Introduction

Sanhe BAM series medium voltage three phase shunt capacitors are used in 50 Hz / 60 Hz AC power system. They are mainly used to improve system power factor, improve power quality of power grid, reduce voltage drop, reduce circuit loss, enhance system transmission capacity, give full play to the efficiency of power generation, transmission and power supply, and are widely used in power grid and industrial and commercial power users.


Sanhe medium voltage three phase shunt capacitors are designed for power factor correction and harmonics filtration at medium voltage. They are all-film dielectric - polypropylene foil impregnated with an environmentally friendly, non-toxic biodegradable insulating oil. There is the aluminium foil as the electrodes. This construction assures minimal looses of the capacitors. Three-phase capacitor are in star - Y connection, The capacitors have internal discharge resistors.


Feature

Polypropylene film adopts double-sided roughening manufacturing technology, low loss, good insulation performance, and the loss tangent value at 20℃ is not more than 0.02%.


The aluminum foil adopts edge folding technology and salient pole design to improve the electric field distribution, reduce the contact resistance, and improve the stability and service life of the capacitor.


The impregnant is non-toxic, environmentally friendly, high aromatic, low viscosity, low freezing point, low dielectric constant, low partial discharge, and long life.


The shell is made of high-quality steel plate by bending and welding, using advanced stamping technology, smooth and beautiful, and high mechanical strength.


Built-in discharge resistor, when cut off from the power supply, the remaining voltage on the capacitor can be reduced from √2UN to 75V and below within 10 minutes.


Technical Prameter

Rated Frequency

60Hz

Average Loss

≤0.2W/kvar

Capacity tolerance

-3%~+3%

Electric medium

Polypropylene full film

Impregnant

not contain chlorinated biphenyls, environmentally friendly and non-toxic

Allow long-term operation under 1.1 times rated voltage

Allow continuous operation at 1.3 times the rated current


Specification sheet

Model

Rated Voltage kV

Rated Capacity kVAR

Frequency

BAM4.16-50-3

4.16

50

60

BAM4.16-100-3

4.16

100

60

BAM4.16-150-3

4.16

150

60

BAM4.16-200-3

4.16

200

60

BAM4.16-250-3

4.16

250

60

BAM4.16-300-3

4.16

300

60

BAM4.16-400-3

4.16

400

60

BAM4.16-500-3

4.16

500

60

BAM4.16-600-3

4.16

600

60

BAM10-50-3

10

50

60

BAM10-100-3

10

100

60

BAM10-150-3

10

150

60

BAM10-200-3

10

200

60

BAM10-250-3

10

250

60

BAM10-300-3

10

300

60

BAM10-400-3

10

400

60

BAM10-500-3

10

500

60

BAM10-600-3

10

600

60

BAM13.8-50-3

13.8

50

60

BAM13.8-100-3

13.8

100

60

BAM13.8-150-3

13.8

150

60

BAM13.8-200-3

13.8

200

60

BAM13.8-250-3

13.8

250

60

BAM13.8-300-3

13.8

300

60

BAM13.8-400-3

13.8

400

60

BAM13.8-500-3

13.8

500

60

BAM13.8-600-3

13.8

600

60

BAM15-50-3

15

50

60

BAM15-100-3

15

100

60

BAM15-150-3

15

150

60

BAM15-200-3

15

200

60

BAM15-250-3

15

250

60

BAM15-300-3

15

300

60

BAM15-400-3

15

400

60

BAM15-500-3

15

500

60

BAM15-600-3

15

600

60

BAM20-50-3

20

50

60

BAM20-100-3

20

100

60

BAM20-150-3

20

150

60

BAM20-200-3

20

200

60

BAM20-250-3

20

250

60

BAM20-300-3

20

300

60

BAM20-400-3

20

400

60

BAM20-500-3

20

500

60

BAM20-600-3

20

600

60

BAM24-50-3

24

50

60

BAM24-100-3

24

100

60

BAM24-150-3

24

150

60

BAM24-200-3

24

200

60

BAM24-250-3

24

250

60

BAM24-300-3

24

300

60

BAM24-400-3

24

400

60

BAM24-500-3

24

500

60

BAM24-600-3

24

600

60

BAM36-50-3

36

50

60

BAM36-100-3

36

100

60

BAM36-150-3

36

150

60

BAM36-200-3

36

200

60

BAM36-250-3

36

250

60

BAM36-300-3

36

300

60

BAM36-400-3

36

400

60

BAM36-500-3

36

500

60

BAM36-600-3

36

600

60


Standard:

IEC60871-1:2014

GB/T 11024.1-2019


Order Guide,

We accept OEM business. If you have requirement for your new build panels, we can give a good price.

If it is retrofit project,please advise the original capacitor name plate, drawing and the reason of replacement. Such, we can recommend you replacement solution.


Why using single star connection instead of double star connection in the small capacity capacitor bank?

1. In engineering design, when the capacity of a single capacitor compensation device is too large so that no suitable fuses cannot be matched,the double star wiring should be selected to reduce the branch current of this capacitor bank. (the capacitor bank can be composed by several single capacitor compensation devices)


As description of clause 5.2 of IEEE std C37.99-2012. 2 and clause 5.2.3, the double star wiring is only used for capacitor bank with its single capacitor compensation device of above 4650kvar.


When the capacity of single capacitor compensation device is small, it is more suitable to use a single star wiring method with simple structure and high reliability.


Previous: 
Next: 

About Us

We have been specialized in power quality,EnMS and Electrical engineering. We take advantages of lean production, product design, engineering management, project service etc.

Quick Links

Product Category

Contact Us

Tel: +86-13502854349
Whatsapp: +86-13418990147
E-Mail: yvonne.zhang@samwha-cn.com

Subscribe Now

Copyright© 2023 Sanhe Power Tech (Shenzhen) Co., Ltd. All Rights Reserved.| Sitemap  | Support By Leadong